Application: Level Measurement of clean liquids (LH842) or slurries/liquid mediums with lots of suspended solids (LH842 Ceramic)
Operating Voltage: 12…30Vdc
Current Consumption: 22mA max.
Output: 4…20mA (2 wire) w/ Hart (optional)
Accuracy: +/- 0.5%
Sensor Material: LH842: 316SS Gauge or Absolute sensor with Silicon or Olive Oil
LH842-Ceramic: Capacitive Ceramic Thick Film Sensor
Pressure Range: 0 to 200 Bar (316SS sensor)
0 to 40 Bar (Ceramic)
Electrical Connection: Terminal connection via 1/2″ NPT Conduit
Cable: Polypropylene cable with vent tube or rigid 316SS rod
Body Material: 316SS or PVC
Operating/ Compensated Temperature: -10 to +80ºC / -10 to +70ºC
-0 to +80ºC / -0 to +70ºC (olive oil sensor)
Overpressure: 3 x F.S.
Class Protection: IP68 Sensor