The SPC98
dry and flush mounted ceramic pressure sensor
uses an aluminum oxide ceramic sensor as
a "dry cell" that is extremely resistant
to overload, aggressive mediums, extreme
min/max temperature, applications with solid
particles and low pressure ranges. It is
designed to be installed at the bottom of
the tank. As opposed to the 316S.S. piezoresistive
cells filled with oil, the process pressure
acts directly on the ceramic diaphragm.
The actual
measuring range of the sensor is determined
by the thickness of the ceramic diaphragm,
which if overloaded, stops on the ceramic
substrate without sustaining damage. Ceramic
cells do not expand and contract nearly
as much as metal, ensuring good temperature
stability.Common features of the SPC98 are
low hysteresis, high repeatability, immunity
to the effects of process builds up and
outstanding resistance to chemical attack.
The SPC98
is often specified for sanitary applications
because if the ceramic cell breaks it will
not contaminate the process medium. The
SPC 98 provides a 4-20mA output and its
body is made of 316S.S.
Pressure ranges
from -1 to 580PSI (-1 to 40 bar) gauge /absolute.