Flow Transmitters
 
 
MODELS:
 
CF 420 - Power Supply: 24VDC
Output: 4-20mA and
PNP/NPN Switch
 

The CF420 model is a flow transmitter that measures the velocity of the flow. It is ideal for use in measurement and control applications. The CF420 provides two output options; a 4-20mA analog output and a PNP/NPN output. For the 4-20mA output, the electronics' module converts the signal from the probe to a 4-20mA analog output, which can be used to indicate flow rate. For the PNP/NPN output, the measured flow rate is compared to the set point value selected by the user and the switch changes state once the set point value has been achieved.

The CF420´s microprocessor based electronics and unique self-calibration program gives the flow transmitter superior temperature compensation, a fast response time and increased long term switch point stability. Even in the event of a power failure, the calibration program will store values for maximum and minimum flows for up to 10 years.

A chain of 8 LED's gives the user a visual indication of the flow rate as well as set point status, and one di-chromatic LED indicates switch point status. In addition, if there is a problem with the unit, the 8 LED's will flash continuously providing troubleshooting information.

The conical shape of the sensor's tip means that the probe can be installed at almost any angle in the pipe and that if the probe is miss-aligned, accuracy will not be affected. The sensing element and connection of the CF420 are made with 316 S.S. and the enclosure is glass filled nylon.

For aggressive mediums the CF420 can be made with Hastelloy-C. We do not coat any of the CF420 models. The CF420 can be made with a great variety of process connections such as threaded, flange, or sanitary.

 
For Dimensions and Wiring Diagram click here
For Ordering Information click here

Measuring Ranges for CF420

The CF420's nominal measuring range is 0.04 to 2.0 m/s. The switch can be set to trip at any value in this range. To calculate the velocity for your application, use the following simple formula:

Q = Flow rate in m³ per second
D = Pipe internal diameter in meters
V = Fluid velocity in meters per second

Please note that the 4-20mA option is scaled over 0 to 2.0 m/s

If the flow rate is in gallons per minute, you can use the factor:
gpm x 0.0000631 = m³/s

 

 
PDF Download
 
  
Catalog::Manual::Data Sheet::
FLOW CF_420FLOW
966 KB 99 KB 499 KB
 

 
Sitron Usa, Inc.
21 W. Nicholai St.
Hicksville, NY 11801
PH: 516-935-8001 / FX: 516-935-6001
e-mail: info@sitron.com
 
  
 
Flow Switches
Flow Transmitters
 
Conductive
Capacitive
 
Vibrating
Tuning Fork
 
  Capacitive
 
 
Pressure
Transmitters
 
 
Submersible
Pressure
Transmitters